Netech Delta 3000 Defib/Pacer/ECG Analyzer
Price: Call
Product Description
-
SALES LEAD TIME: 14-21 Days(BUILT TO ORDER).
-
WARRANTY: One Year
-
ACCESSORIES: Hard Carrying Case, ECG Snap Adapters, Operator Manual, Calibration Certificate, AC Adapter, (2) 9V Batteries, Paddle Adapter Set3 TESTERS DELIVERED IN 1 BOX – DEFIB ANALYZER (INCLUDING AED & BIPHASIC), PACER ANALYZER (EXTERNAL & TRANSTHORACIC), ECG ANALYZER. GREAT VALUE & CONVENIENT PACKAGE!
OVERVIEW:
The Delta 3000 combines the complete testing functions of a defibrillator tester, a pacemaker analyzer, and an ECG arrhythmia simulator into one compact, lightweight, and easy to use instrument.No other instrument delivers the performance testing power of the Delta 3000. It will test all defibrillators, all external pacemakers including transcutaneous and transvenous and all ECG equipment. The built-in user selectable test loads eliminate the need to carry extra modules to test the transcutaneous pacers.
The Delta 3000 delivers unsurpassed biomedical testing capabilities in one instrument.
HIGHLIGHTS:
* Compact, Lightweight and Rugged.
* Simple, Menu Driven Operation.
* Large, Easy to Read Display.
* Simultaneous Display of All Test Measurements.
* Dedicated Print key for Immediate Documentation.
* RS 232 Interface.
* Battery or AC Operation.Test Functions:
Defibrillator Tester: Tests All Defibrillators – Semi -Automatic, Automatic, and those with Bi-Phasic Waveforms.
* Measures: Energy, Peak Voltage, Peak Current, and Cardio Sync. Time.
* Storage and Playback of Output Waveforms.Pacemaker Analyzer: Tests All External Pacemakers – Transthoracic and Transvenous Pacers.
* Measures: Amplitude, Rate, Pulse Width, Pulse Energy, Sensed and Paced Refractory Periods.
* 50 and 60 Hz Immunity Tests.
* Transthoracic Test Load: Fixed 50 Ohm or 12 User Selectable Loads to 1000-Ohms.
* A / V Pacer Test Load: 500 Ohms.ECG Simulator: Tests All ECG Equipment.
* 12 lead ECG. User selectable Rates and Amplitudes.
* Performance Waveforms: Sine, Square, Triangle & Pulse
* 12 Arrthymia WaveformsSPECIFICATIONS:
Defibrillator Analyzer:
Energy Measurement:Load: 50 Ohms +/- 1%
Range (High): 900 Joules, Res. 1 J.
Resolution: 1 Joules
Range (Low): 0 – 100
Resolution: 0.1 Joules.
Accuracy: +/- 2% of the Reading
Plus 1J for Hi Range or
Plus 0.5J for Low Range.
Maximum voltage: 5200
Maximum Current: 100 Amp (H)
Sync. Time: 0-250 ms.
Waveform Output:
Real Time: Output1000: 1Stored:
Discharge waveform expanded 200:1 and is repeated 8 seconds. It can be viewed through the paddles and through the ECG High Level Output.Pacemaker Analyzer:
Transcutaneous:
Test Load: 50 Ohms (Fixed) and Variable 100 to 1000 Ohms user selectable.
Current: 1 to 200 mA
Accuracy: +/- 5% +. 5 mA
Pulse Width: 0.5 to 80 ms.
Accuracy: +/- 1% +.1 ms.
Refractory: 20 – 500 ms
Accuracy: +/- 2 % or +10msAtrial and Ventricular:
Test Load: 500 Ohms +/-1%
Current: 1 to 25 mA
Accuracy: +/- 5% +. 5 mA.
Pulse Rate: 30 to 800 ppm.
Pulse Width: 0.5 to 80 ms.
Accuracy: +/- 1% +.1 ms.
Refractory: 20 – 500 ms
Accuracy: +/- 2 % or +10ms
Immunity Test: 50/60 HzECG Arrhythmia Simulator:
ECG: Normal Sinus Rhythm
Rate: 30, 60, 90, 120, 240 BPMPerformance:
Sine, Square, Triangle and Pulse
Rate: 0.5 1, 2, 10, 15, 20, 25, 40 Hz.
Arrhythmias: VFBC, VFBF, VTAC, AFIB, PVC, PVC1, PVC2, BGY, RBB, AFIB, ATRFT, NSR.
Waveform Output: 12 Lead ECG and Paddle and HI level Output Jacks.Power Requirements: Two 9-Volt Alkaline Battery or AC adapter.
Dimensions: 10 x 11 x 2.25 inches (L x W x H)(25.4 x 27.9 x 5.7 cm)
Weight: 4 lbs (1.9 Kg)