Netech LKG 601 Electrical Safety Analyzer

Price: Call

Product Description

  • WARRANTY:   One-Year Manufacturer Warranty

  • ACCESSORIES:  Carrying Case, Test Lead, Operator Manual, Calibration Certificate

  • SALES LEAD TIME:  14-21 DAYS

 GENERAL DESCRIPTION:

The LKG 601, Electrical Safety Analyzer is an extremely easy to use portable Electrical Safety Analyzer designed specifically for testing non-ECG equipment. Ground resistance, leakage current, and instrument current test measurements are displayed on its large LCD. With its unique operating features, the LKG 601, Electrical Safety Analyzer out performs all other basic electrical safety analyzers. To insure accuracy, each test has calibrated test points. The accessible instrument fuse solves the maintenance problems of built-in fuses. The selectable test load provides testing flexibility.For the routine electrical safety testing of all your electrical equipment, the LKG 601, Electrical Safety Analyzer is simply the best selection.

 FEATURES:

  • Portable
  • Large LCD Display
  • Accessible Line Fuse
  • Calibrated Test Points
  • Selectable Test Loads
  • 15 and 20 Amp Capability
  • Point-to-Point Testing
  • Complies with AAMI/ESI 1993
  • LED Unit of Measure Indicator

MEASUREMENTS:

  • Ground Resistance
  • Case Leakage Current
  • Earth Leakage Current
  • Instrument Current

SPECIFICATIONS

Leakage Current: 

0-1999 micro amps. All Current measurements are made through the AAMI/ANSIESI – 1985 or IEC 601 – 1 test load. The meter readings correspond to the true RMS value of the current.

Accuracy:

+/-1% of reading, +/-1 LSD DC to 1 kHz,
+/-2.5% of reading, +/-1 LSD 1 kHz to 100 kHz,
+/-5% of reading, +/-1 LSD 100 kHz to 1 mHz.

Resistance:

     0 to 1999 milli ohms. Accuracy is +/-1% of reading, +/-1 LSD

Device Current :

     0 to 19.99 amps. Accuracy is +/-2% of FS, +/-1LSD

Measures:

Ground Resistance, Internal and External Leakage Current, and Instrument Current.

Test Receptacle:

Hospital Grade 110V AC – 15 amp or 220V AC 10 amp. The rocker polarity switch selects NORMAL, OFF and REVE RSEPolarity to the test receptacle, and a momentary Neutral switch will open the neutral line to the test receptacle.

General 

Display:

3½ Digit LCD Display

Power Requirements:

110V AC 50 – 60 Hz, 15 amps

220V AC, 50 – 60 Hz, 10 amps

Physical Dimensions:

5.5 x 3.25 x 2.5 inches

(13.75 x 8.13 x 6.25 cms)

Weight:

1 lbs (0.45 kg)

Ambient Temperature:

Operating Range: 59° to 95° F (15° to 40° C)
Storage Temperature: 0° to 122° F (-20° to 60° C)
Relative Humidity: 90% (max) at temperatures