Netech MiniSim 1000 Multiparameter Simulator
Brand: Netech Corp
Product Code: Netech MiniSim 1000 Multiparameter Simulator
Availability: Indent 1-2 bulan
Harga : CALL
Product Description
Multi-Parameter Patient SimulatorThe MiniSim 1000 is a powerful, comprehensive patient simulator with a number of unique features. It provides a full 12 lead ECG signal with more than 40 arrhythmias, dual blood pressure, respiration, and temperature. It also delivers square, sine, and a triangle performance waveforms.MiniSim 1000 arrhythmia selections include pacer waveforms, ST segment changes, and both atrial and ventricular waveforms. The dual blood pressure and respiration waveforms are synchronized to the ECG and track with all arrhythmia selections. Multiple static and dynamic pressure readings are selectable as per apnea events
Operation of the hand – held MiniSim 1000 is simple via menu driven tactile keys utilizing a large LCD Display. The instrument may be either AC or Battery operated.
FEATURES:
Over 40 Arrhythmias
ECG Performance Waveforms
Dual Blood Pressure
Respiration
TemperatureEasy to Use
Small, Compact Size
Menu Driven Operation
Large LCD Display
Tactile Keypad
Battery or AC Operation
Rate: 30, 60, 70, 80, 90, 100,120, 150, 180, 210, 240, 270, 300, 350 BPM
Amplitude: 0.15 to 5mV
High Level Output: 0.5 Volt/mV of Low Level (Lead II)Performance Waveforms:
Sine, Triangle, Square
Rate: 0.1 to 100 Hz
0.1 to 1 Hz in 0.1 Hz increments
1 to 10 Hz in 1 Hz increments
10 to 100 Hz in 10 Hz incrementsTall T Wave
Test Waveform@ 70 BPM
Atrial Pacer
Ventricular Pacer*
Paced Rhythms – Variable from 0.1 to 2mS
R Wave detection – Variable form 10 to 120mS.
Pulse:
2mS Pulse of 1mV amp @ 4 sec intervals
Pacers
ST Segment Analysis:
ST Elevation and Depression
ST Depression Positive and Negative Slope
Myocardial Infarction
Arrhythmias:
Atrial
Ventricular
Blocks
Respiration:
Normal Physiological Simulation:
Base Line Impedance: 250, 500, 750, 100 Ohms
Delta Impedance: 0.1, 0.5, 1.0, 1.5 Ohms
Rates: 15, 30, 60, 120 BPM
Apnea: Off, Continuous, 12 Seconds and 32 Seconds Apnea-Bradycardia
Accuracy: Delta Impedance 5% of selection
Rate: 1% of selection
Blood Pressure:
Impedance: 350 Ohms
Excitation: 2 to 16 Volts
Sensitivity: 5uV/V/mmHg
Static: 0, 5, 10, 20, 25, 30, 40, 50, 100, 150, 200, 300 mmHg.
Dynamic: 50/10, 60/20, 70/30, 80/40, 100/60, 120/80 mmHg.
Accuracy: +/-2% FS. +/-1 mmHg
Synchronized with all normal sinus rates
Physiologically track all arrhythmia selections.
Temperature:
Compatibility: YSI 400/700
25/37 Degree Centigrade
Accuracy: +/-1% of reading
General:
Display: 16 Character 2 Line LCD
Key Pad: 8 tactile keys Ð F1, F2, F3, F4, >, <, ON/OFF, Menu
Output Connectors ECG: 10 Banana Jacks
High Level: 3.5mm Phono Jack
Pressure: 5 contact circular Din
Temperature: 3.5mm Stereo Jack
Physical Size: 5 1/2 x 31/2 x 1 1/2 inches
Case: High Impact Plastic
Weight: 10 Oz.
Power:
9 Volt Alkaline/AC adapter (Optional).
Battery Life 40 Hours Continuous.