Biotek ISA601PRO XL International Electrical Safety Analyzer

Brand: Fluke Biomedical
Product Code: ISA601PROXL
Availability: Indent 1-2 bulan

Harga : CALL

Product Description

PREOWNED:    Very Good Condition

WARRANTY:    12 Months

ACCESSORIES: Power Cord, Test Leads, Operator Manual, Calibration Certificate, 2 Rolls of paper

 

FEATURES

  • Multiple enclosure-leakage points
  • Multiple patient-applied-part types
  • Power ON/OFF delay
  • DC only for patient- and auxiliary-leakage tests
  • User-programmable test sequences
  • Manual, auto, step, and computer-control modes
  • ASCII data transfer
  • Memory for up to 1000 device-information records
  • EN60601-1, EN601010-1, and AAMI test loads (user selectable)

 

SPECIFICATIONS:

 

Voltage: Range:  0 to 300 V True RMS

Accuracy: DC-100 Hz+/- 1.5% of reading +/- LSD

 Insulation Resistance: Range: 0.5 to 400.0 Mohms

                                  Accuracy:  +/- 5% of reading +/- LSD

Current Consumption: Range:  0 to 15 A ac True RMS

                                  Accuracy:  +/- 5% of reading +/- LSD

Mains on Applied Part:Applied Voltage:  > or = 110 % of mains voltage

                                  Accuracy:  +/- 2% of reading +/- 6 micro A

Supply Voltage:90 to 265 VAC, Autoswitching

Protective Earth Resistance:Range:  0.000 to 2.999 ohms

Accuracy:  +/- 5% of reading +/- 4 mohms (1A, 10A, and 25A test currents)         IEC601-1 and AAMI

Range:  0 – 8000 microA True RMS

Leakage Currents                    

Accuracy:  (per IEC601-1 or AAMI filter)

-DC – 1 kHz +/- 1% of reading +/- 1 microA

-1 to 100kHz +/- 2% of reading +/- 1 microA

-100 kHz to 1 MHz +/- 5% of reading +/- 1 microA

DC-Only Frequency Response:  DC – 5 Hz (approx)

EC1010-1 Leakage Current:       Range: 0 – 16000 microA True RMS

(For some leakage tests, displayed range may be 0 – 9999 when using IEC1010 test load)

Accuracy:  (per IEC1010-1 figure A.1 filter

-DC – 1 kHz +/- 2% of reading +/- 2 microA

-1 to 100 kHz +/- 4% of reading +/- 2 microA

 -100 kHz to 1 MHz +/- 10% of reading +/- 10 microA

DC-Only Frequency Response:  DC – 5 Hz (Approx)

ECG Simulation and ECG Complex:  30, 60, 120, 180, 240 BPM

Performance Testing:Performance Pulse:  30, 60, BPM, 63 ms pulse width  (600 – 700 micros rise and fall time)

Sine Waves:  10, 40, 50, 60, 100 Hz

Square Waves:  0.125, 2.000 Hz (50% duty cycle)

Triange Wave:  2 Hz, 2 mV

Arrhythmia: Atrial Fibrillation, Atrial Flutter, Atrial Tachycardia, Idioventricular, PVC1, R on T, Run

 Ventricular Fibrillation, Ventricular Tachycardia

Performance: +/- 2% of reading for rate or +/- 5% of reading for amplitude, fixed at 1 mV peak

on a Lead II ECG connection (except for triange wave, which is 2mV peak to peak)

Dimensions: 16.62 in L x 11.75 in W x 5.56 in H

                        42.2 cm L x 30 cm W x 14.1 cm H

Weight:  17lb

              7.7kg