890

ECC 890 X-ray Dose/Rate/Exposure Time Meter

Brand: Electronic Control Concepts (ECC)
Product Code: 890
Availability: Indent 1-2 bulan

Harga :CALL

Product Description

WARRANTY: One year warranty
INCLUDED ACCESSORIES: Calibration Certificate, Operator manual, Hard Carrying Case
DESCRIPTION:
The ECC Model 890 Dose Meter / Exposure Time Meter is specifically designed to measure x-ray dose. The instrument is used to measure the effective dose produced by diagnostic x-ray generators. The ECC Model 890 is a solid-state, digital instrument designed specifically for service personnel in assessing the performance of radiation generators and the effective dose delivered by the x-ray generator under specific test conditions. This instrument measures the amount of x-ray radiation delivered to a specific area and measures the length of an exposure. The Model 890 can be used for dental x-ray units, radiographic and fluoroscopic x-rays. The Model 890 automatically resets at the beginning of each exposure, holding the reading until the next exposure. There is no need to reset the meter before each measurement. The Model 890 is a small hand held battery operated unit. Each x-ray exposure is displayed on a 2×12 digit liquid crystal display (LCD). The operator can select between English (mR) and SI (uGy) units. Radiation is detected by a solid state detector and electronic circuit. The instrument works for half-wave, full-wave, multiphase or DC (constant potential) x-ray generators. When a measurement is being made, the Model 890 has the capability of automatically determining the type of x-ray that is being measured. It is not necessary for the user to program correction factors for different types of x-ray waveforms.
FEATURES:
  • Measures x-ray dose
  • Measures dose rate
  • Measures exposure time
  • Selectable English and Metric Units
  • Easy to Use
  • Works with AC or DC x-rays
  • No need to set for AC/DC
  • High Accuracy
  • Battery Operated
  • Two Year Warranty
  • Custom carrying case option
  • Solid state digital design
  • Durable ABS plastic case
APPLICATIONS:
  • Measure effective dose
  • Measure patient equivalent dose
  • Calibration of X-ray
  • Quality Assurance
  • Measurement of exposure time
  • Radiation Safety Measurement
  • Troubleshooting and repair of x-rays
  • Maintain quality of x-ray
SPECIFICATIONS:
Dose Range
  • 1mR to 2000mR
  • 0.01mGy to 20mGy
  • 10uGy to 20000uGy
Dose Accuracy
  • 3% +/- 1mR
Exposure Time
  • 2% +/- 2 millisecond -20 to 5000ms
Connection:
  • None
Display:
  • 0.21″ (5.5mm) Liquid Crystal
  • 2 line, 12 Character Alphanumeric
Controls:
  • ON / OFF / Units Switch
Power:
  • 9 Volt battery accessible from bottom of case
  • Low battery indicator
Battery Life:
  • 48 hours continuous
  • Typical nine months of normal use
Warranty:
  • 2 years from ship date
Physical Size:
  • 80 x 147 x 40 mm
  • 3.15 x 5.8 x 1.6 inches
Weight
  • 350g, (0.81 lb)
Recalibration:
  • Annual Calibration Recommended
Operating Conditions:
  • +10 degrees to 40 degrees C
  • 50 degrees to 104 degrees F
  • Up to 75% Relative Humidity
  • Storage 0 degrees C to 50 degrees C