Delta3000-500x500

Netech Delta 3000A Defib/Pacer Analyzer w/ECG Simulator

Price: Call

Product Description

  • WARRANTY:  One Year
  • SALES LEAD TIME:  14 – 21 Days
  • ACCESSORIES:  Hard Carrying Case, Operator Manual(CD), Battery Eliminator, Calibration Certificate, 10 Banana Jacks to ECG Snap Adapters, 2 9V Batteries, Universal Paddle Adapters
  OVERVIEW
The Delta 3000A is a compact instrument that tests defibrillators and transcutaneous pacemakers. It is also a 12 lead ECG arrhythmia simulator.
The instrument tests defibrillators with monophasic or bi-phasic waveforms and all AEDs. It will test transcutaneous pacemkaers and includes 12 built-in user selectable test loads. The 12 lead ECG simulator includes 12 arrhythmias plus sine, square, and triangle performance waveforms. The Delta 3000A may be easily upgraded to add the capability of testing transvenous pacemakers. Operation of the Delta 3000A is via easy to follow menus and eight tactile feel keys. Instructions and measurements are displayed on the large four line LCD display. A print key outputs test measurements to the RS 232 serial port.
The Delta 3000A is a complete instrument. It is delivered in a hard carrying case with paddle adapters and two set of universal connectors, an AC adapter, batteries, an instruction manual, a Certificate of Calibration, and the Netech two year warranty. The Delta 3000A is a unique instrument that meets the demanding requirements of the biomedical engineer in a rugged, light weight package. Its upgradeability places it in a class clearly beyond the competition.

HIGHLIGHTS
• Compact, Lightweight Case
• Simple, Menu Driven Operation
• Large Easy to read LCD Display
• Simultaneous Display of All Test Measurements
• Dedicated Print Key for Immediate Documentaion
• RS 232 Interface
• Battery or AC Operation
• Two-Year Warranty

MEASUREMENTS
Defibrillator Tester:- Tests all Defibrillators – Semi, Automatic, and those with Bi-Phasic Waveforms.
• Measures: Energy, Peak Voltage, Peak Current, and Cardioversion.
• Storage and Playback of output waveforms
• Built-in 50 Ohm Test Load.
• Built-in User Selectable Test Loads to 1000 Ohms.

Pacemaker Analyzer:- Tests All Transthoracic Pacemakers.

• Built-in 50 Ohm Test Load
• Built-in User Selectable Test Loads to 1000 Ohms.
• Amplitude, Rate, Pulse Width Accuracy Tests.
• Sensed and Paced Refactory Period Tests.
• 50 and 60 Hz Immunity Tests.
• Measures Pulse Energy.

ECG Simulator:- Tests all ECG Equipment.
• 12 lead ECG.
• Performance Waveforms: Sine, Square, Triangle.
• 12 Arrhythmias.
• 8 Selectable Rates and Amplitudes

STANDARD ACCESSORIES
• Hard Carrying Case
• AC Adapter
• Universal Paddle Adapter
• Shrouded Banana Plugs (set of 2)
• User Manual
• Certificate of Calibration
• Instruction Manual

OPTIONAL ACCESSORIES
• Interface cables for various Maufacturers
• Palm Interface Software

SPECIFICATIONS:

Defibrillator Analyzer
Energy Measurement: Load: 50 Ohm ± 1 %
Range (High): 900 J, Res.1 J
Resolution: 1 Joules
Range (Low): 0 – 100
Resolution: 0.1 Joules
Accuracy: +/- 2% of the reading
+ 1 J for Hi Range or
+ 0.5 J for Low Range
Maximum Voltage: 5200 V
Maximum Current: 100 Amp (H)
Sync. Time: 0 – 250 ms
Waveform Output:
Real Time: Output 1000 : 1 Stored.
Discharge waveform expanded 200:1 and is repeated 8 sec. It can be viewed through the paddles and through the ECG High Level Output

Pacemaker Analyzer
Transcutaneous:
Test Load: 50 Ohm (Fixed) and variable 100 to 1000 Ohms user selectable
Current: 1 to 200 mA
Accuracy: +/- 5% + 0.5 mA
Pulse Width: 0.5 to 80 ms
Accuracy: +/- 1% + 0.1 ms
Refractory: 20 – 500 ms
Accuracy: +/- 2% or + 10 ms
Atrial and Ventricular:
Test Load: 500 Ohms
Current: 1 to 25 mA
Accuracy: +/- 5% + 0.5 mA
Pulse Rate: 30 to 800 ppm.
Accuracy: +/- 1% + 0.1 ms
Refactory: +/- 20 – 500 ms
Accuracy: +/- 2% or 10 ms
Immunity Test: 50 / 60 Hz

ECG ArrhythmiaSimulator

ECG: Normal Sinus Rhythm.
Rate: 30, 60, 90, 120, 240
Performance: Sine, Square, Triangle and Pulse
Rate: 0.5, 1, 2, 10, 15, 20, 25, 40 Hz
Arrhythmias:
VFBC, VFBF, VTAC, AFIB, PVC, PVC1, PVC2, BGY, RBB, AFIB, ATRFT, NSR
Waveform Output: 12 Lead ECG and Paddle and High Level Output Jacks.

General
Power Requirements:
Two 9V Alkaline Batteries Or AC Adapter

Dimension:
10 x 11 x 2.25 inches
(25.4 x 27.9 x 5.7 cm)