    OVERVIEW:
    MiniSim Model 1000
    Multi-Parameter Patient Simulator

    The MiniSim 1000 is a powerful, comprehensive patient simulator with a number of unique features. It provides a full 12 lead ECG signal with more than 40 arrhythmias, dual blood pressure, respiration, and temperature. It also delivers square, sine, and a triangle performance waveforms.

    MiniSim 1000 arrhythmia selections include pacer waveforms, ST segment changes, and both atrial and ventricular waveforms. The dual blood pressure and respiration waveforms are synchronized to the ECG and track with all arrhythmia selections. Multiple static and dynamic pressure readings are selectable as per apnea events

    Operation of the hand – held MiniSim 1000 is simple via menu driven tactile keys utilizing a large LCD Display. The instrument may be either AC or Battery operated.

    FEATURES:

    12 Lead ECG
    Over 40 Arrhythmias
    ECG Performance Waveforms
    Dual Blood Pressure
    Respiration
    Temperature

    Easy to Use
    Small, Compact Size
    Menu Driven Operation
    Large LCD Display
    Tactile Keypad
    Battery or AC Operation

    SPECIFICATIONS:
    ECG Normal Sinus:
    Rate: 30, 60, 70, 80, 90, 100,120, 150, 180, 210, 240, 270, 300, 350 BPM
    Amplitude: 0.15 to 5mV
    High Level Output: 0.5 Volt/mV of Low Level (Lead II)

    Performance Waveforms:
    Sine, Triangle, Square
    Rate: 0.1 to 100 Hz
    0.1 to 1 Hz in 0.1 Hz increments
    1 to 10 Hz in 1 Hz increments
    10 to 100 Hz in 10 Hz increments

    Tall T Wave
    Test Waveform@ 70 BPM
    Atrial Pacer
    Ventricular Pacer*
    Paced Rhythms – Variable from 0.1 to 2mS
    R Wave detection – Variable form 10 to 120mS.

    Pulse:
    2mS Pulse of 1mV amp @ 4 sec intervals

    Pacers
    ST Segment Analysis:
    ST Elevation and Depression
    ST Depression Positive and Negative Slope
    Myocardial Infarction

    Arrhythmias:
    Atrial
    Ventricular
    Blocks

    Respiration:
    Normal Physiological Simulation:
    Base Line Impedance: 250, 500, 750, 100 Ohms
    Delta Impedance: 0.1, 0.5, 1.0, 1.5 Ohms
    Rates: 15, 30, 60, 120 BPM
    Apnea: Off, Continuous, 12 Seconds and 32 Seconds Apnea-Bradycardia
    Accuracy: Delta Impedance 5% of selection
    Rate: 1% of selection

    Blood Pressure:
    Impedance: 350 Ohms
    Excitation: 2 to 16 Volts
    Sensitivity: 5uV/V/mmHg
    Static: 0, 5, 10, 20, 25, 30, 40, 50, 100, 150, 200, 300 mmHg.
    Dynamic: 50/10, 60/20, 70/30, 80/40, 100/60, 120/80 mmHg.
    Accuracy: +/-2% FS. +/-1 mmHg
    Synchronized with all normal sinus rates
    Physiologically track all arrhythmia selections.

    Temperature:
    Compatibility: YSI 400/700
    25/37 Degree Centigrade
    Accuracy: +/-1% of reading

    General:
    Display: 16 Character 2 Line LCD
    Key Pad: 8 tactile keys Ð F1, F2, F3, F4, >, <, ON/OFF, Menu
    Output Connectors ECG: 10 Banana Jacks
    High Level: 3.5mm Phono Jack
    Pressure: 5 contact circular Din
    Temperature: 3.5mm Stereo Jack
    Physical Size: 5 1/2 x 31/2 x 1 1/2 inches
    Case: High Impact Plastic
    Weight: 10 Oz.

    Power:
    9 Volt Alkaline/AC adapter (Optional).
    Battery Life 40 Hours Continuous.
    Display Indicates Low Battery.